WLAN-Status 29.11.2026 03:41:18
Access Points mit 11 bis 25 Sessions innerhalb der vergangenen 4 Wochen
Berlin-Mitte > Geschwister-Scholl-Str. 1, Grimm-Zentrum > 7. Obergeschoss|
Name: AP-GZ-07.112-01 Hardware: AP3915i Serial Number: 1935Y-1251100000 Uptime: 2 d 21:50:46 h Last succ. Poll: 29.11.2026 03:40:09 Basic PwrUsage: 5700mW SavedEnergy: 51.775,37 Wh (since: 24.08.2022 23:14:01) IP: 172.19.173.197 eth0: dc:b8:08:70:28:f7 eth0 In Errors: 0 SW Version: 10.51.23.0003 Home-Controller: ECA-GZ Active/Backup-Ctrl: ECA-GZ / ECA-UdL6 Poll-Timeout: 3s R1 5 GHz Ch: 108 (5540 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ac W.: Auto (20/40/80 MHz) Max-W: 80 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 1% Rx Frames Ø: 1% AP Tx Ø: 1% Avg Noise: -90 dBm Beacon Interval: 100 ms R2 2.4 GHz Ch: 1 (2412 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11gn W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 2% Rx Frames Ø: 5% AP Tx Ø: 1% Avg Noise: -76 dBm Beacon Interval: 100 ms WLAN-Sessions: 1 (R1: 1) 5.0ac: 1 valid/invalid/unknown IPs: 1 / 0 / 0 auth/not auth Clients: 1 / - Min (1d / 7d / 28d): 1 / 0 / 0 Max (1d / 7d / 28d): 4 / 5 / 11 |
| ||||||||||||||||||||||||
Connected to: ICX-GZ-7401 e 1/1/3 Location: Berlin-Mitte > Geschwister-Scholl-Str. 1, Grimm-Zentrum > 7. Obergeschoss ENERGY_SAVING_ENABLED / IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
|
Name: AP-GZ-07.112-02 Hardware: AP3915i Serial Number: 1842Y-1177000000 device unreachable probably powered off due to energy saving Last succ. Poll: 29.11.2026 00:09:59 Basic PwrUsage: 5500mW SavedEnergy: 50.431,73 Wh (since: 25.08.2022 00:14:02) IP: 172.19.172.183 eth0: 94:9b:2c:13:e8:9e SW Version: 10.51.23.0003 Home-Controller: ECA-GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 0 / 4 / 22 |
| ||||||||||||||||||||||||
Connected to: ICX-GZ-7401 e 1/1/4 Location: Berlin-Mitte > Geschwister-Scholl-Str. 1, Grimm-Zentrum > 7. Obergeschoss ENERGY_SAVING_ENABLED / IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
|
Name: AP-GZ-07.113-03 Hardware: AP3915i Serial Number: 1935Y-1272200000 device unreachable probably powered off due to energy saving Last succ. Poll: 29.11.2026 00:09:59 Basic PwrUsage: 5700mW SavedEnergy: 50.600,21 Wh (since: 25.08.2022 00:14:02) IP: 172.19.173.87 eth0: dc:b8:08:70:2d:16 SW Version: 10.51.23.0003 Home-Controller: ECA-GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 9 / 16 / 17 |
| ||||||||||||||||||||||||
Connected to: ICX-GZ-7401 e 1/1/6 Location: Berlin-Mitte > Geschwister-Scholl-Str. 1, Grimm-Zentrum > 7. Obergeschoss ENERGY_SAVING_ENABLED / IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
|
Name: AP-GZ-07.113-02 Hardware: AP3915i Serial Number: 1935Y-1270000000 device unreachable probably powered off due to energy saving Last succ. Poll: 29.11.2026 00:09:59 Basic PwrUsage: 5600mW SavedEnergy: 49.529,11 Wh (since: 25.08.2022 00:14:02) IP: 172.19.172.154 eth0: dc:b8:08:70:2c:a8 SW Version: 10.51.23.0003 Home-Controller: ECA-GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 15 / 17 / 18 |
| ||||||||||||||||||||||||
Connected to: ICX-GZ-7401 e 1/1/5 Location: Berlin-Mitte > Geschwister-Scholl-Str. 1, Grimm-Zentrum > 7. Obergeschoss ENERGY_SAVING_ENABLED / IGNORE_A_WIDTH / IGNORE_ZERO_TX_ON_A |
Hilfe - Aktualisierungsintervall: 5 Minuten
Version 14.2.3, syj, 03.06.2026
Datenerhebung: 29.11.2026 03:39:02 Erzeugt: 29.11.2026 03:41:18 PID 192298