WLAN-Status 22.10.2026 05:21:47
Access Points mit 26 bis 50 Sessions innerhalb der vergangenen 4 Wochen
Berlin-Mitte, Campus Nord > Invalidenstr. 42|
Name: AP-Inv42-R1131 Hardware: AP310i Serial Number: 2037Y-1065200000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.10.2026 22:09:21 Basic PwrUsage: 6100mW SavedEnergy: 66.357,30 Wh (since: 28.09.2022 22:14:01) IP: 172.19.174.201 eth0: 20:9e:f7:76:f8:e3 SW Version: 7.8.6.0-002R Home-Controller: ECA-GZ WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 3 / 34 / 42 |
| ||||||||||||||||||||||||
Connected to: B5-Inv42-HG-1133b ge.1.47 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
|
Name: AP-Inv42-R1042 Hardware: AP310i Serial Number: 2038Y-1395600000 Uptime: 5 d 23:32:46 h Last succ. Poll: 22.10.2026 05:20:07 Basic PwrUsage: 6000mW SavedEnergy: 9.578,27 Wh (since: 24.08.2022 22:14:02) IP: 172.19.174.121 eth0: 20:9e:f7:77:32:72 eth0 In Errors: 0 SW Version: 7.8.6.0-002R Home-Controller: ECA-GZ Active/Backup-Ctrl: ECA-GZ / ECA-UdL6 Poll-Timeout: 3s R1 5 GHz Ch: 108 (5540 MHz) Pwr-Lvl : 18 dBm Radio-Type: IEEE 802.11ax W.: 40 MHz Max-W: 40 MHz Bond.: Yes DCS: monitor Ch Busy Ø: 2% Rx Frames Ø: 0% AP Tx Ø: 1% Avg Noise: -91 dBm Beacon Interval: 100 ms R2 2.4 GHz Ch: 9 (2452 MHz) Pwr-Lvl : 12 dBm Radio-Type: IEEE 802.11ax W.: 20 MHz Max-W: 20 MHz Bond.: No DCS: monitor Ch Busy Ø: 4% Rx Frames Ø: 1% AP Tx Ø: 1% Avg Noise: -98 dBm Beacon Interval: 100 ms WLAN-Sessions: 1 (R2: 1) 2.4n: 1 valid/invalid/unknown IPs: 1 / 0 / 0 auth/not auth Clients: 1 / - Min (1d / 7d / 28d): 1 / 0 / 0 Max (1d / 7d / 28d): 22 / 50 / 50 |
| ||||||||||||||||||||||||
Connected to: B5-Inv42-K42 ge.2.46 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
|
Name: AP-Inv42-Ostbau-2.303 Hardware: AP3915i Serial Number: 1918Y-1071900000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.10.2026 22:09:21 Basic PwrUsage: 6100mW SavedEnergy: 67.092,59 Wh (since: 24.08.2022 23:14:01) IP: 172.19.174.102 eth0: dc:b8:08:6c:e8:36 SW Version: 10.51.23.0003 Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 0 / 5 / 26 |
| ||||||||||||||||||||||||
Connected to: ICX-Inv42-Ostbau-2217 e 1/1/43 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Ostbau ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
|
Name: AP-Inv42-R1038 Hardware: AP310i Serial Number: 2201Y-1167000000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.10.2026 22:09:21 Basic PwrUsage: 5900mW SavedEnergy: 65.114,48 Wh (since: 14.09.2022 22:14:02) IP: 172.19.174.113 eth0: b0:27:cf:cc:d8:57 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 10 / 36 / 36 |
| ||||||||||||||||||||||||
Connected to: B5-Inv42-K42 ge.2.48 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A | |||||||||||||||||||||||||
|
Name: AP-Inv42-R1152 Hardware: AP310i Serial Number: 2037Y-1384200000 device unreachable probably powered off due to energy saving Last succ. Poll: 21.10.2026 22:09:21 Basic PwrUsage: 6100mW SavedEnergy: 69.299,10 Wh (since: 06.10.2022 22:14:01) IP: 172.19.174.203 eth0: 20:9e:f7:77:39:02 SW Version: 7.8.6.0-002R Home-Controller: ECA-UdL6 WLAN-Sessions: 0 Min (1d / 7d / 28d): 0 / 0 / 0 Max (1d / 7d / 28d): 25 / 32 / 32 |
| ||||||||||||||||||||||||
Connected to: B5-Inv42-HG-1133b ge.1.45 Location: Berlin-Mitte, Campus Nord > Invalidenstr. 42 > Hauptgebäude ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A |
Hilfe - Aktualisierungsintervall: 5 Minuten
Version 14.2.3, syj, 03.06.2026
Datenerhebung: 22.10.2026 05:19:01 Erzeugt: 22.10.2026 05:21:47 PID 438536