? Zielgruppen ?
?

Humboldt-Universität zu Berlin - Computer- und Medienservice

WLAN-Status 24.11.2026 23:51:19

Access Points mit 11 bis 30 Sessions innerhalb der vergangenen 24 Stunden

Berlin-Mitte, Campus Nord > Invalidenstr. 118
Name: AP-Inv118-R507
Hardware: AP310i
Serial Number: 2038Y-1349300000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 24.11.2026 22:09:23
Basic PwrUsage: 5800mW
SavedEnergy: 8.937,51 Wh (since: 02.10.2022 21:29:02)
IP: 172.19.183.205
eth0: 20:9e:f7:77:29:67
SW Version: 7.8.6.0-002R
Home-Controller: ECA-GZ
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 19 / 26 / 26

SNMP Instanzen ECA-GZAP: 621 Radio 1: 5962 Radio 2: 5961
Controller Site: Invaliden118
Connected to: ICX-Inv118-310 e 1/1/47
Location:  Berlin-Mitte, Campus Nord > Invalidenstr. 118
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Inv118-R217
Hardware: AP310i
Serial Number: 2038Y-1346500000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 24.11.2026 22:09:23
Basic PwrUsage: 6100mW
SavedEnergy: 66.851,11 Wh (since: 24.08.2022 22:14:02)
IP: 172.19.183.201
eth0: 20:9e:f7:77:28:db
SW Version: 7.8.6.0-002R
Home-Controller: ECA-GZ
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 21 / 21 / 25

SNMP Instanzen ECA-GZAP: 626 Radio 1: 6002 Radio 2: 6001
Controller Site: Invaliden118
Connected to: ICX-Inv118-110 e 3/1/22
Location:  Berlin-Mitte, Campus Nord > Invalidenstr. 118
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Inv118-R315
Hardware: AP310i
Serial Number: 2038Y-1338300000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 24.11.2026 22:09:23
Basic PwrUsage: 5800mW
SavedEnergy: 69.338,28 Wh (since: 24.08.2022 22:14:02)
IP: 172.19.183.204
eth0: 20:9e:f7:77:27:41
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 19 / 22 / 36

SNMP Instanzen ECA-GZAP: 620 Radio 1: 5954 Radio 2: 5953
Controller Site: Invaliden118
Connected to: ICX-Inv118-310 e 1/1/45
Location:  Berlin-Mitte, Campus Nord > Invalidenstr. 118
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Inv118-R010
Hardware: AP3915i
Serial Number: 1744Y-1296100000
Uptime: 11 d 17:58:40 h
Last succ. Poll: 24.11.2026 23:49:55
Basic PwrUsage: 5900mW
SavedEnergy: 134,42 Wh (since: 12.06.2026 03:19:01)
IP: 172.19.183.197
eth0: b4:2d:56:25:62:6e
eth0 In Errors: 0
SW Version: 10.51.23.0003
Home-Controller: ECA-UdL6
Active/Backup-Ctrl: ECA-UdL6 / ECA-GZ
Poll-Timeout: 3s
R1 5 GHz Ch: 60 (5300 MHz)
  Pwr-Lvl : 16 dBm
  Radio-Type:  IEEE 802.11ac
  W.: Auto (20/40/80 MHz) Max-W: 20 MHz Bond.: Yes
  DCS: monitor
  Ch Busy Ø: 1%
  Rx Frames Ø: 1%
  AP Tx Ø: 1% 
  Avg Noise: -87 dBm
  Beacon Interval: 100 ms
R2 2.4 GHz Ch: 1 (2412 MHz)
  Pwr-Lvl : 15 dBm
  Radio-Type:  IEEE 802.11gn
  W.: 20 MHz Max-W: 20 MHz Bond.: No
  DCS: monitor
  Ch Busy Ø: 12%
  Rx Frames Ø: 14%
  AP Tx Ø: 1% 
  Avg Noise: -81 dBm
  Beacon Interval: 100 ms
WLAN-Sessions: 1  (R1: 1)
  5.0ac: 1
valid/invalid/unknown IPs: 1 / 0 / 0
auth/not auth Clients: 1 / -
  Min (1d / 7d / 28d): 1 / 0 / 0
  Max (1d / 7d / 28d): 29 / 39 / 53
IndexRadio / BandIf-MACStatusSSIDSessions
0Radio 1 5 GHz ath0 802.11nacb4:2d:56:23:aa:d0Upeduroam
1Radio 1 5 GHz ath1 802.11nacb4:2d:56:23:aa:d1UpStornoHUB1
10Radio 2 2.4 GHz ath10 802.11ngb4:2d:56:23:aa:c0Up_Free_Wifi_Berlin
11Radio 2 2.4 GHz ath11 802.11ngb4:2d:56:23:aa:c1Upeduroam
12Radio 2 2.4 GHz ath12 802.11ngb4:2d:56:23:aa:c2UpStornoHUB

SNMP Instanzen ECA-UdL6AP: 667 Radio 1: 6329 Radio 2: 6330
SNMP Instanzen ECA-GZAP: 667 Radio 1: 6329 Radio 2: 6330
Controller Site: Invaliden118
Connected to: ICX-Inv118-110 e 1/1/48
Location:  Berlin-Mitte, Campus Nord > Invalidenstr. 118
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Inv118-R016
Hardware: AP310i
Serial Number: 2038Y-1345600000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 24.11.2026 22:09:23
Basic PwrUsage: 5800mW
SavedEnergy: 71.187,86 Wh (since: 24.08.2022 22:14:02)
IP: 172.19.183.195
eth0: 20:9e:f7:77:28:ae
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 11 / 13 / 16

SNMP Instanzen ECA-GZAP: 624 Radio 1: 5986 Radio 2: 5985
Controller Site: Invaliden118
Connected to: ICX-Inv118-110 e 3/1/21
Location:  Berlin-Mitte, Campus Nord > Invalidenstr. 118
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Inv118-R410
Hardware: AP310i
Serial Number: 2038Y-1356300000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 24.11.2026 22:09:23
Basic PwrUsage: 5900mW
SavedEnergy: 65.820,12 Wh (since: 24.08.2022 22:14:02)
IP: 172.19.183.198
eth0: 20:9e:f7:77:2a:c5
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 22 / 32 / 32

SNMP Instanzen ECA-GZAP: 623 Radio 1: 5978 Radio 2: 5977
Controller Site: Invaliden118
Connected to: ICX-Inv118-310 e 1/1/46
Location:  Berlin-Mitte, Campus Nord > Invalidenstr. 118
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A
Name: AP-Inv118-R117
Hardware: AP310i
Serial Number: 2038Y-1346600000
device unreachable
probably powered off due to energy saving
Last succ. Poll: 24.11.2026 22:09:23
Basic PwrUsage: 5800mW
SavedEnergy: 67.009,77 Wh (since: 24.08.2022 22:14:02)
IP: 172.19.183.202
eth0: 20:9e:f7:77:28:e0
SW Version: 7.8.6.0-002R
Home-Controller: ECA-UdL6
WLAN-Sessions: 0  
  Min (1d / 7d / 28d): 0 / 0 / 0
  Max (1d / 7d / 28d): 23 / 24 / 28

SNMP Instanzen ECA-GZAP: 627 Radio 1: 6010 Radio 2: 6009
Controller Site: Invaliden118
Connected to: ICX-Inv118-110 e 3/1/23
Location:  Berlin-Mitte, Campus Nord > Invalidenstr. 118
ENERGY_SAVING_ENABLED / IGNORE_ZERO_TX_ON_A


Hilfe - Aktualisierungsintervall: 5 Minuten
Version 14.2.3, syj, 03.06.2026
Datenerhebung: 24.11.2026 23:49:01 Erzeugt: 24.11.2026 23:51:19 PID 2119981